Description
Shampaine 5100B Major Surgical Tables
The 5100B major surgical tables provide flexible articulation for complete patient positioning. Through the use of Electroluminescent (EL) technology, the 5100 series tables are the only tables available with “Full-Function Key Illumination”. These tables have a longitudinal slide feature for full length image amplification. Each of the five table sections, including the 15″ leg extension, come standard with a built-in x-ray cassette tunnel. These tables are capable of returning to the horizontal position (true level) through the convenience of one button activation. The 5100B is battery-powered. The table may be operated with or without the power cord connected. Mains power is only required to recharge the battery. The battery recharge system will restore completely discharged batteries to 80% of full charge within eight hours (8) and bring the table to a full charge within twelve (12) hours of continuous charging.
Design Features
The base houses the following components:
- Low Voltage Control Box
- Pump/Motor Assembly
- Batteries
- Hydraulic Manifold Block
- Solenoid Valves
- AC Power Input Module
- Manual Foot Pump
Applications
These tables are designed for use in major surgical suites, ambulatory theaters and medical operatories where accurate patient positioning is critical. They are particularly adaptable to those procedures requiring mobile image amplification equipment without use of a special x-ray top. They also incorporate a backlit primary hand pendant that will facilitate proper patient positioning in low-level lighting situations (i.e. – endoscopy procedures).
Standards and Codes
These tables have been designed to conform to the requirements of:
- Underwriters Laboratories
- Canadian Standards Association
- International Electrotechnical Commission
Patient Positioning Capabilities
- Patient lifting capacity is 500 lbs. (227 kg). This means the TABLE UP, TABLE DOWN, Trendelenburg, and REVERSE Trendelenburg functions can be utilized with a 500 lb. patient positioned on the table with the tabletop centered over the column.
- Patient articulation capacity is 400 lbs. (181 kg). This means that a 400 lb. patient can be moved into any of the standard procedural positions.
Control System
The primary control system is a dual microprocessor configuration with one circuit board located in the pendant receptacle box and one located in the primary hand pendant. These microprocessors allow actuation of the solenoid valves through the primary hand pendant controls.
Primary Hand Pendant
In addition to the standard table functions, the hand pendant includes the following special features: Return to Level, Patient Orientation, Battery Strength Indicator and Drawer/Service LED Indicators. The Return to Level feature moves the table to a horizontal (true level) position in the correct anatomical sequence. Patient Orientation adjusts all functions relative to the patient’s position on the table (Normal or Reversed). The Battery Strength Indicator continuously monitors the status of the battery and indicates when the table should be plugged in to recharge the battery. The DWR Indicator will illuminate to indicate that the Auxiliary Pendant Drawer is open, diverting power away from the Primary Hand Pendant. The SERV Indicator advises that there is a potential problem, requiring notification of an authorized Service Representative.
Specifications:
- Length: 72-1/2″ (1842mm) [88-3/8″ (2245mm) with removable leg extension]
- Width: 19-3/4″ (502mm) [21-3/4″ (552mm) with side rails]
- Height: 28″ to 43″ (711mm to 1092mm)
- Base: 37-7/8″ L (962mm) × 23-5/8″ (W) (600mm) × 5-3/8″ (H) (136mm)
- Distance from Floor to Bottom of Table with floor locks extended: 2-9/16″ (65mm)
- Trendelenburg: Up to 25°
- Reverse Trendelenburg: Up to 25°
- Lateral Tilt: Up to 18°
- Back Section: Adjustable 30° below horizontal to 90° above horizontal
- Kidney Elevator: Extendible up to 2-1/2″ (64mm)
- Leg Section: Adjustable from 95° below horizontal to 70° above Headrest Section: Adjustable from 120° below horizontal to 120° above in 15° increments
- Electrical Power Requirements: 115 VAC, 50/60 Hz, 4A, Single- Phase or 220 VAC, 50/60 Hz, 2A, Single Phase
- Weight (Net): 750 lb (341 kg)
- Weight (Gross): 900 lb (409 kg)
Reviews
There are no reviews yet.