Description
Awareness Technology STAT FAX 2600 Microplate Washer
STAT FAX 2600 Microplate Washer washes flat round and v-bottom plates and strips.
For added versatility Stat Fax 2600 now offers these added features:
- Built-in plate mixing function with programmable mix time.
- Individual row selection for partial plate washing. Select individual rows to wash and skip used wells.
- Optional dual wash bottle system for added versatility and convenience.
Standard Features
- Fully automatic.
- Washes flat, round, and V-bottom plates and strips.
- No user adjustments required. Automatic calibration, alignment, and last row detection.
- Carriers come in two styles, 3×12 for break-apart microwell strips, and an optional 3×8 for non-break-apart microwell strips.
- 6 ready-to-run wash progams.
- Large, non-volatile memory stores 50 user-specified wash protocols.
- Precision operation with constant monitoring of vacuum and pressure. Pump cycles only when necessary for quiet operation.
- Programmable automatic rinse cycle.
- Ready to run: bottles, aerosol shield, 8-way manifold included.
- NRTL and CE certified.
- Optional: 12 and 16 position wash heads available.
Features:
Stat Fax 2600 Microplate WasherMicroplate washers are used to control the procedure of washing experimental samples arranged in plate-based formats. Compared to manual alternatives, advanced washers improve the speed and accuracy of many washing procedures. They are used in many applications such as ELISA, cell-based assays and microsphere-based assays. There are suitable washers for every lab’s needs – from hand-held devices to fully automated systems.
The fully automatic Stat Fax 2600 Microplate Washer by Awareness technology is a popular product. It washes flat, round, and V-bottom plates and strips. This NRTL- and CE-certified device requires no user adjustments to operate. It performs automatic calibration, alignment, and last row detection. Its carriers come in two styles:
- 3×12 for break-apart microwell strips, and
- Optional 3×8 for non-break-apart microwell strips
This model ensures precision operation with constant monitoring of vacuum and pressure, with pump cycles needed only for quiet operation.
Stat Fax 2600 Microplate Washer – Standard Features
- Ready to run: bottles, aerosol shield, 8-way manifold
- Built-in plate mixing function with programmable mix time
- Large, non-volatile memory stores 50 user-specified wash protocols
- 6 ready-to-run wash programs
- Programmable automatic rinse cycle
- Optional: 12 and 16 position wash heads available
For greater versatility and convenience, the washer comes with additional features such as: built-in plate mixing function with programmable mix time, individual row selection for partial plate washing, and optional dual wash bottle system. The internal pumps ensure quiet functioning.
When buying a microplate washer, it is important for labs to focus choose the most appropriate instrument for their application and one that will fit in with their current workflow. Purchase from a reliable dealer in medical laboratory equipment is necessary to ensure prompt, efficient post-sales service.
Clinical laboratories use microplate washers in many applications such as enzyme-linked immunosorbent assays (ELISA or EIA), cell-based assays and microsphere-based assays. The Stat Fax® 2600 Microplate Washer from Awareness Technology is a fully automatic system designed for use with ELISA. This includes processing clinical diagnostic assays, multistep washing, rinsing, and soaking.
Along with accepting a wide array of standard microplates and micro strip trays, and accommodating partially filled micro strip trays, this microprocessor-controlled instrument can also work with microwells having flat, round, or V-bottom configurations.
- Six ready-to-run wash programs
- Programmable automatic rinse cycle
- Automatic calibration, last row detection and alignment
- Precision operation with continuous monitoring of pressure and vacuum
- Ready to run: bottles- aerosol shield- 8-way manifold included
- No user adjustments required
- Automatic calibration, alignment, and last row detection
This fully programmable washer provides multistep combinations of dispense, aspirate, combined aspirate/dispense, and timed soak cycles. The unit’s large, non-volatile memory stores 50 user-specified wash protocols. For volumes larger than the capacity of the wells or to reduce bubbles, a top-wash feature is included so the wash solution may be aspirated off the top as it is being dispensed. The instrument can be programmed to automatically perform a rinse operation at a particular time of day, and can be used in the direct mode whereby wash operations are selected via the built-in keypad.
The Stat Fax® 2600 makes operation convenient with its user-programmable tests. Along with the 8-probe combination dispense/aspirate wash head, the washer is also supplied with wash, rinse, and waste bottles utilizing integral electronic level sensors, and an aerosol shield. For efficient customer support and reliable post-sales service, laboratories should purchase Microplate Readers/Washers from an established lab equipment supplier.
Reviews