Skip to content Skip to footer

Echo Portable Vital Signs Monitor

Ultra-lightweight and portable with a 10 hr battery. Pre-op/post-op vital signs monitor

Type: Vital Signs Monitors

Compare
Category: Product ID: 6008

Description

Ultra-lightweight and portable with a 10 hr battery.

Pre-op/post-op vital signs monitor

The accurate, cost-effective Avante Echo vital signs monitor is available in configurations with your choice of SpO2, NIBP and Temperature. The portable monitor has multi-parameter functionality suited for out-patient care and doctor’s offices.

Features:

  • NOW with Covidien Quick Temp Technology
  • 5.7 inch high resolution display for easy reading
  • Flexible configurations
  • Built-in rechargeable Lithium-ion battery for 10 hours of continuous working
  • Optional thermometer for obtaining temperature in approximately 15 seconds
  • Real-time parameters measurement display with trend table for easy reviewing
  • Bi-directional communications with central station by wired or wireless network
  • Suitable for adult, pediatric and neonatal patient
  • Optional Nellcor Oximax™
  • PR measurement (from SpO2/ NIBP)
  • Optional recorder

Specifications:

General

  • Size: 200.8mm (L) × 241mm (H) × 189 mm (D)
  • Weight: 3 kg
  • Display: 5.7 inches,LCD
  • Color TFT resolution: 640X480
  • Power Supply: 100-240 VAC, 50/60HZ
  • Pmax=70VA FUSE T 1.6AL
  • Battery Type: Lithium-ion
  • Voltage: 14.8 V DC Capacitance: 4,400 mAh
  • Working period: Color TFT 480min
  • Rechargeable period: < 360min
  • Recorder: (Optional)
  • Record Width: 48 mm

NIBP

  • Method: Oscillometric
  • Mode: Manual, Auto, Continuous
  • Measuring Interval in AUTO Mode: 1/2/3/4/5/10/15/30/60/90/120/240/480 Min
  • Continuous: 5min, interval is 5s
  • Measuring Type: Systolic Pressure, Diastolic Pressure, Mean Pressure, Measuring Range
  • Adult Mode:
    • SYS: 40~270mmHg
    • DIA: 10~215mmHg
    • MAP: 20~235mmHg
  • Pediatric Mode:
    • SYS: 40~200mmHg
    • DIA: 10~150mmHg
    • MAP: 20~165mmHg
  • Neonatal Mode:
    • SYS: 40~135mmHg
    • DIA: 10~100mmHg
    • MAP: 20~110mmHg
  • Cuff Pressure measuring Range: 0~290mmHg
  • Pressure Resolution: 1mmHg
  • Maximun mean error: 5mmHg
  • Maximum Standard deviation: 8mmHg
  • Entire Measuring Period 30~45s typical (depend on HR/motion disturbance)
  • Dual Overpressure protection:
    • Adult: 297 3mmHg
    • Pediatric: 240 3mmHg
    • Neonatal: 145 3mmHg
  • PR:
    • Measuring Range: 40~240bpm
    • Resolution: 1bpm
    • Accuracy: 3bpm or 3% of the maximum
    • IEC 60601-2-30

SpO2

  • Resolution: 1 %
  • Accuracy
  • Adult (including Pediatric):
    • 2% 70%~100% SpO2
    • Undefined 0~70% SpO2
  • Neonate:
    • 3% 70%~100% SpO2
    • Undefined 0~70% SpO2
  • Measuring Range: 0 ~ 100 %
  • Alarm Range: 0 ~ 100 %
  • Pulse Rate:
    • Measuring and Alarm Range: 30 ~ 300bpm
    • Resolution: 1bpm
    • Accuracy: 3bpm
    • Data update period: 2s
    • ISO 9919

Reviews

There are no reviews yet.

Be the first to review “Echo Portable Vital Signs Monitor”

Your email address will not be published. Required fields are marked *