Description

The GE Innova 3131 is a fully integrated biplane angiographic x-ray system suitable for interventional x-ray procedures. Ideal for cardiology and neurology, the unparalleled technology Innova 3131 ensures accurate and consistent high imaging performance. A variety of safety features are incorporated into the system as well to ensure a smooth and comfortable procedure.

Features:

  • Dose monitoring
  • Holds up to eight monitors
  • Tube chiller
  • Detector chiller
  • Smart Fluoro
  • Real-time 3D imaging and reconstruction
  • Max dose reduction setting to decrease exposure
  • Anti collision software and sensors provided for patient safety
  • C-arm units (including Gantries, control cabinets and table-side control boxes)
  • Collimators
  • X-ray tubes: Performix 160A
  • Image detection units
  • Cardiac Table Omega IV or Angio Table Omega V
  • TSUI smart box and smart handle
  • Table side status control
  • Innova Central touch screen
  • X-ray high-frequency and high-voltage generators: JEDI 100
  • In-room and control monitors
  • Accessories include: table head extender, armboard, IV pole, quick strap, head holder, Clear-Vu arm support, mattress and mattress slicker, shoulder rests, and footrests. For more information, contact your representative.

Specifications:

Generator

  • Maximum peak power: 100 kW
  • Maximum average power: 3.2 kW
  • Range of high frequency: 20 kHz – 60 kHz
  • kV-mA range: kV from 40 kV – 125 kV; 1000 mA maximum
  • Large focus maximum mA: 1000 mA
  • Large focus maximum power: 100 kW
  • Small focus maximum mA: 400 mA
  • Small focus maximum power: 48 kW
  • Compressed focus maximum mA: 200 mA
  • Compressed focus maximum power: 16 kW

Gantry – LC Positioner (Frontal)

  • L-arm rotates on vertical axis ± 100° (± 95° motorized limit set)
  • Offset C-arm permits -117°/+105° RAO/LAO rotation
  • L-arm rotation speed: 10° per second
  • C-arm permits 50° cranial and 45° caudal angulation of the imaging system
  • Combination of C-arm and L-arm movements permits ±55° cranial and caudal angulations
  • SID fully motorized: 8.9 cm/s (3.5 in/s)
  • SID range 89 cm to 119 cm (35 in to 46.8 in)
  • Travel distance of 30 cm (11.8 in)
  • X-ray Tube Focal Spot to isocenter 72 cm (28.3 in)

Gantry – LP Positioner (Lateral)

  • C-arm permits angulations from 2° LAO to 115° LAO
  • C-arm pivot permits from 45° cranial to 90° caudal angulations of the imaging system
  • Rotation speed of C-arm/C-arm pivot: 0° to 10° per second
  • X-ray tube Focal Spot to Isocenter range: 71 cm to 88 cm (27.9 in to 34.6 in)
  • SID range: 84 cm to 137 cm (33.1 in to 54 in)
  • Detector and tube lift speed: 89 mm/s

Omega Table

  • Can support table weight of 204 kg (450 lbs)
  • Tabletop length: 333 cm (131 in)
  • Width: 46 cm (18 in) in patient trunk area, 67 cm (26.4 in) max
  • Horizontal float movement: 8-way
  • Horizontal motorized movement: 2-way
  • Longitudinal speed: 0 to 15 cm/s
  • Longitudinal travel: 170 cm (67 in)
  • Equivalent fluoroscopic coverage: 186 cm (73 in)
  • Transverse travel: ±14 cm (5.5 in)
  • Vertical travel: 30 cm (12 in)
  • Vertical travel above floor: 78 cm to 108 cm (30.7 in to 42.5 in)
  • Vertical speed: 2 cm/s at 50 Hz, 2.5 cm/s at 60 Hz
  • Table base: 61 cm x 52 cm (24 in x 20.5 in)
  • Table rotation: ±180°

Physical

  • Temperature range: 15° C to 32° C (59° F to 89.6° F)
  • The maximum load a table-side rail can handle is 40 kg (88.18 lbs)

Accessories:

  • Smart box
  • Smart box with cables
  • TSSC
  • TSSC with cables
  • IVUS PIM (with metallic support)
  • IVUS Joystick
  • IVUS Control
  • IVUS Touch Pad
  • IVUS Pimmette
  • 3D mouse box
  • Cable support
  • Table panning device
  • Injector head
  • Rad-shield